IEC 60079 -14 Electrical Installations in Hazardous Areas

IEC 60079 -14 Electrical Installations in Hazardous Areas

Read or Download IEC 60079 -14 Electrical Installations in Hazardous Areas PDF

Similar electrical & electronics books

Digital Systems and Applications (The Computer Engineering Handbook, Second Edition)

New layout architectures in desktops have exceeded expectancies. Limits, that have been as soon as regarded as primary, have now been damaged. electronic platforms and purposes information those concepts in platforms layout in addition to state-of-the-art purposes which are rising to exploit the fields more and more refined features.

Electric Power Distribution System Engineering

A brief experiment of any book shop, library, or on-line bookseller will produce a large number of books protecting energy structures. although, few, if any, are absolutely dedicated to strength distribution engineering, and none of them are actual textbooks. Filling this vacuum within the strength process engineering literature, electrical energy Distribution method Engineering broke new flooring.

Introduction to Experimental Infrared Spectroscopy: Fundamentals and Practical Methods

Infrared spectroscopy is usually understood to intend the technology of spectra in relation to infrared radiation, specifically electromagnetic waves, within the wavelength zone happening intermediately among noticeable gentle and microwaves. Measurements of infrared spectra were offering worthwhile info, for quite a few clinical learn and business reports, for over part a century; this is often set to proceed within the foreseeable destiny.

Extra info for IEC 60079 -14 Electrical Installations in Hazardous Areas

Example text

Alternatively, testing shall be carried out in a “gas-free” situation. --`,````,,,```,,,,`,,,``,,,,,-`-`,,`,,`,`,,`--- NOTE Whenever portable electrical apparatus is used in a hazardous area, extreme care should be taken to avoid unnecessary risks. Unless specifically permitted by the certification documents for portable electrical apparatus or unless other suitable precautions are taken, spare batteries should not be taken into the hazardous area. 1 Danger from live parts In order to avoid the formation of sparks liable to ignite the explosive gas atmosphere, the possible inadvertent contact with bare live parts other than intrinsically safe parts shall be prevented.

Metallic enclosures of intrinsically safe apparatus need not be connected to the equipotential bonding system, unless required by the apparatus documentation or to prevent accumulation of static charge. Installations with cathodic protection shall not be connected to the equipotential bonding system unless the system is specifically designed for this purpose. NOTE Potential equalization between vehicles and fixed installations may require special arrangements, for example where insulated flanges are used to connect pipelines.

During use, such apparatus should not be transferred from a zone of lower risk to a zone of higher risk unless it is suitably protected for the higher risk. In practice, however, such a limitation may be difficult to enforce; it is recommended, therefore, that all portable apparatus meet the requirements of the highest risk. Similarly, the apparatus group and temperature classification should be appropriate for all the gases and vapours in which the apparatus may be used. Ordinary industrial portable apparatus should not be used in a hazardous area unless the specific location has been assessed to ensure that potentially flammable gas or vapour is absent during the period of use (“gas-free” situation).